top of page

COLORMETER

DS-700d

DS-700d in Charging/Calibration base
DS-700d Quick changeable apertures

The DS-700d Portable Spectrophotometer is a precision instrument designed for detailed colour measurement.

Dual Optical Path: The DS-700d utilises a dual optical path system. This functionality improves measurement accuracy by allowing the instrument to sample light from two different paths, yielding precise and reliable data.

Intelligent Auto Calibration: The DS-700d includes an auto calibration system that adapts the device's settings to maintain consistent accuracy across varied conditions.

400-700nm Wavelength: It operates within the visible light spectrum, spanning 400-700nm wavelengths, ensuring comprehensive colour data that aligns with human visual perception.

10nm Intervals: Readings are captured at 10nm intervals, offering detailed colour analysis and the ability to discern minor colour differences.

Integrated Camera: An incorporated camera aids in targeted measurements, streamlining the process and minimising potential errors.

Connectivity: The DS-700d offers Bluetooth connectivity for the dedicated CM App and compatibility with our specialised Windows software, catering to various data management preferences.

Touchscreen: Its 3.5" TFT touch screen interface provides a straightforward user interaction, simplifying operations.

Overall, the DS-700d Portable Spectrophotometer is engineered for users seeking precision, consistency, and a technical approach to colour measurement.

Design Samples

Dual optical path array sensor

The dual optical path design monitors the energy fluctuation of the light source whilst measuring the sample data, to reduce interference during the measurement and obtain better measurement repeatability. The usage of large-area dual-array sensors provides a higher spectral response sensitivity, and ensures fast measurement speed, accuracy, stability and consistency between multiple devices.

Dual optical path diagram

Intelligent auto calibration

The white calibration tile is made of Zirconium dioxide (ZrO2) which has a reflectance of more than 90% which results in a more stable calibration.
When the instrument is placed in the intelligent calibration base unit, the instrument will automatically calibrate using the built-in white calibration tile, so there is no need to manually calibrate which saves time and effort. The white tile is made using ZrO2 to ensure excellent resistance to scratch, discoloration and weathering over time.

Charging and Calibration base with White tile
Paint Pots and Color Wheel
DS-700d
Utrecht Building

Intelligent auto aperture recognition

Three apertures (11mm/6mm/1*3mm) are supplied as standard. Apertures are simple to change- no tools are necessary.

 


 

More than 30 kinds of colour indices and 37 kinds of illuminants
DS-700d provides a variety of colour indices and evaluation illuminants that comply with international standards.

A variety of light sources and colour indices can also be chosen via the CM app or PC software

3x Apertures in various sizes
Light Source
DS-700d
Payment Objects
DS-700d

400-700nm Full Wavelength Balanced LED+UV

The DS-700d adopts a full wavelength balanced LED and UV as the illuminant, ensuring sufficient spectral distribution in the visible and ultraviolet bands. Any materials with fluorescent can also be measured.

Spectral wavelength

10nm Resolution Grating Spectroscopy Technology

The grating combined with the array sensor made by the innovative MEMS process makes colour measurement more accurate based on the 10nm spectral resolution.

Colour, reflection
Modern Workspace
DS-700d

Supports Android, IOS and Windows 

DS-700d connectivity options

Camera for aperture view

Display screen showing camera view with large aperture
Display screen showing camera view with medium aperture
Display screen showing camera view with small aperture

DS-700d Technical Specifications

  • Geometry: d/8, SCI+SCE(diffused illumination,8° viewing, Specular Component Included, Specular Component Excluded)

  • Repeatability: Chromaticity value:
    Standard deviation within ΔE*ab ≤ 0.025
    Average :dE*ab< 0.025
    Max. :dE*ab≤ 0.04
    (when a white tile is measured 30 times at 5-seconds interval)
    Reflectance: Standard deviation < 0.08%

  • Inter-instrument agreement: ΔE*ab<0.25
    (BCRA Series Ⅱ, average measurement of 12 tiles)

  • Display Resolution: 0.01

  • Illumination Area/Aperture: 
    MAV:Φ8mm/Φ11mm
    SAV:Φ4mm/Φ6mm
    MINI:1*3mm

  • Colour Spaces and Indices: Reflectance, CIE-Lab, CIE-LCh, HunterLab, CIE Luv, XYZ, Yxy, RGB, Colour difference(ΔE*ab, ΔE*cmc, ΔE*94,ΔE*00),WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Blackness (My,dM),Colour Fastness, Tint,(ASTM E313-00),Color Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Colour strength

  • Illuminants: A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84,ID50,ID65,LED-B1,LED-B2
    LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2

  • Light Source: LED(Full wavelength balanced LED) + UV

  • Camera for aperture viewing: Yes

  • Software: Android, IOS, Windows

  • Observer: 2°,10°

  • Sphere Size: 40mm

  • Standards: Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7

  • Spectroscopic method: Grating spectroscopy

  • Sensor: Dual array sensor

  • Wavelength Interval: 10nm

  • Wavelength: 400-700nm

  • Wavelength Range: 0-200%

  • Reflectance Resolution:0.01%

  • Measurement Time: < 2s

  • Interface: USB, Bluetooth

  • Screen: IPS Full Colour Screen,3.5 inches

  • Battery: Rechargeable, 8000 times continuous tests, 3.7V/3000mAh

  • Lamp Lifetime: 10 years,1million tests

  • Language: English & Chinese

  • Storage Memory: App Mass Storage

bottom of page